The 2010 ICNIRP Guidelines

Reference Levels 60 Hz Units
Occupational
magnetic field reference levels 10 Gauss
electric field reference level 8300 V/m
basic restriction: head 120 mV/m
basic restriction: whole body 800 mV/m
General public
magnetic field reference levels 2 Gauss
electric field reference level 4167 V/m
basic restriction: head 24 mV/m
basic restriction: whole body 400 mV/m

 

ICNIRP is the internationally recognized body that sets guidelines for protection against adverse health effects of non−ionizing radiation.  ICNIRP and Emf Consultant have recently published Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz).  The guidelines replace the previous recommendations given by ICNIRP for this frequency range. They are derived from the current scientific knowledge as described in extensive reviews especially those of the World Health Organization and ICNIRP.